  page 1 of 3 models ? high power density power supply (open frame) ? certifcation according to iec/en/es 60601-1 3rd edition for 2xmopp ? low leakage current <75 a rated for bf applications ? emc emission an immunity to iec 60601-1-2 edition 4 ? risk management process according to iso 14971 including risk management fle ? acceptance criteria for electronic assem- blies according to ipc-a-610 level 3 ? protection class l and ll ? operating up to 5000m altitude ? ready to meet erp directive, no load power consumption ? 5 year product warranty the tpp 15 ac/dc power supplies feature a reinforced double i/o isolation sys - tem according to medical safety standards iec/en/es 60601-1 3rd edition for 2 x mopp approved for an operating altitude of 5000 m. the earth leakage current is below 75 a what makes the units suitable for bf (body foating) ap - plications. the excellent effciency of up to 88.5% offers a high power density in the packaging format 1.0 x 2.6. the full load operating temperature range covers C40c to +55c while it goes up to 85c with 50% load derating. the units operate in compliance to the medical emc emission and immunity levels according to latest standard iec 60601-1-2 4th edition. prepared c b scheme es 60601-1 u l 60950 -1 order code output power (max.) output voltage output current (max.) effciency (typ.) tpp 15-103a-j 13.2 w 3.3 vdc 4000 ma 84.0 % tpp 15-105a-j 5.0 vdc 3000 ma 86.0 % tpp 15-109a-j 9.0 vdc 1670 ma 86.0 % tpp 15-112a-j 12 vdc 1250 ma 87.0 % tpp 15-115a-j 15 w 15 vdc 1000 ma 87.0 % tpp 15-124a-j 24 vdc 625 ma 88.0 % tpp 15-136a-j 36 vdc 417 ma 88.0 % tpp 15-148a-j 48 vdc 313 ma 88.5 % models http://www.tracopower.com ac/dc medical power supply tpp 15 series, 15 watt
page 2 of 3 input specifications input voltage range C ac range (universal input) 85 C 264 vac (derating of 4%/v below 90 vac input required) C dc range 120 C 370 vdc input frequency 47 C 63 hz input current at full load C at 115 vac / 230 vac 0.45 a max. / 0.30 a max. input protection t1.6 a/250 vac (internal fuse in both line & neutral) input inrush current C at 230 vac 40 a max. zero load power consumption 0.05 w max. (acc. erp directive) output specifications voltage adjustability 10% voltage set accuracy 1% regulation C input variation 0.2% max. C load variation (0 - 100%) 3.3 & 5 vdc model: 0.7% ma x. other models: 0.5% max. minimum load not required temperature coefficient 0.02%/k hold-up time C vin = 115 vac 8 ms typ. start-up time 500 ms max. rise time 20 ms typ. ripple and noise - single output model 3.3 & 5.0 vdc outputs: 40 mvp-p typ. w. cap. 10f/50v 1206 x5r mlcc (20mhz bandwidth) 9, 12 & 15 vdc output: 70 mvp-p typ. w. cap. 10f/50v 1206 x5r mlcc 24 & 36 vdc output: 100 mvp-p typ. w. cap. 10f/50v 1206 x5r mlcc 48 vdc output: 140 mvp-p typ. w. cap. 1f/100v 1206 x7r mlcc transiente response C peak deviation 5% max. (25% load step change) C recovery time 500 s typ. overvoltage protection 125 C 140% of nominal vout current limitation at 145% iout typ. short circuit protection continuous (automatic recovery), hiccup general specifications temperature ranges C operating C40c to +85c with derating C storage C40c to +85c output power derating C temperature 1.67 %/k above +55c (up to 85c max.) C low input voltage 4.0 %/v below 90 vac humidity (non condensing) 5 C 95 % rel. h max. altitude during operation 5000 m switching frequency (at 230 vac) 85 khz typ. (10 khz) (pulse width modulation) isolation voltage C input / output (60 sec.) 4000 vac (2 x mopp insulation) leakage current (at 264 vac/60hz) 75 a max. isolation resistance (at 500 vdc) 100 mohm min. reliability C calculated mtbf at +25c acc. to mil-hdbk-217f 3000000 h tpp 15 series, 15 watt http://www.tracopower.com all specifcations valid at nominal input voltage, full load and +25c after warm-up time unless otherwise stated.
www .tracopowe r. com ? copyright 2017 traco electronic ag sp ec i?cati ons can be changed wi thout noti ce! page 3 of 3 general specifications (continued) emi emission C conducted & radiated input surpression en 55011 limits to iec 60601-1-2 4th editon en 55032 class b (internal filter) C harmonic current emissions iec / en 61000-3-2, class a C voltage flicker iec / en 61000-3-3, (class tba.) emc immunity en 55024, en 60601-1-2 4th edition C esd (electrostatic discharge) en 61000-4-2, air 15 kv, contact 8 kv, perf. criteria a C radiated immunity en 61000-4-3, 20 v/m, perf. criteria a C fast transient en 61000-4-4, 2 kv, perf. criteria a C surge en 61000-4-5, 1 kv perf. criteria a C conducted immunity en 61000-4-6, 20 vrms, perf. criteria a C magnetic field immunity en 61000-4-8, 30 a/m, perf. criteria a C voltage dip and interruptions en 61000-4-11, safety standards and certification ul 60950-1, iec/en 60950-1, iec/en 60601-1 3rd edition, ansi/aami es60601-1:2005(r)2012 C certification documents www.tracopower.com/overview/tpp15 shock and vibration vibration acc. iec 60068-2-6 shock acc. iec 60068-2-27 environmental compliance C reach www.tracopower.com/products/reach-declaration.pdf C rohs rohs directive 2011/65/eu protection class class i & ii prepared connection pin connector outline dimensions 66.2 (2.61) 3.35 (0.13) 59.5 (2.34) front view 25.4 (1.00) 2.92 (0.11) 19.56 (0.77) 15.70 (0.62) 2.8 (0.11) output input 3.2 (0.13) input output pin single pin dual 1 line 1 Cvout 3 neutral 2 +vout pin connectors weight: 19.0 g (0.67 oz) input: jst series mates with jst crimp terminal: bvh-21t-p1.1 and terminal housing: vhr-3n utput: jst series mates with jst crimp terminal: bvh-21t-p1.1 and terminal housing: vhr-2n each one of the 4 srew holes can be used as a pe connection for class i applications print thickness: 1.0 mm (0.04 inch) dimension in mm, () = inch tolerances: x.x 0.5 (0.02) x.xx 0.25 (0.01) tpp 15 series, 15 watt rev. august 18, 2017


▲Up To Search▲   

 
Price & Availability of TPP15-124A-J

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X